Logo
Kvadrat Kytola Oilan A4

The Kytola OILAN A4 is an online oil water content analyzer which instantly shows changes in the lubrication oil water content. It detects water leaks in their early stages and helps to prevent expensive failures and down time of the lubricated machinery and equipment. OILAN A4 is therefor an excellent instrument for supporting preventative maintenance.

For sales or commercial inquiries please contact us at marine@insatech.com.

Contact us now

Extend service intervals

Marine and offshore equipment is operated in highly abrasive and harsh conditions. So, for safety reasons strategic vessel equipment in the business have a fixed five-year dry-docking interval. But if approved propulsion condition monitoring requirements are met, the class requirement can be waived. Using the Kytola Oilan A4 water in oil analyzer the service interval can be extended by up to two years, thus creating remarkable savings in both avoided downtime and maintenance costs.

Measure free water and minor changes in the oil

One of the main advantages is that whereas most analyzers measure humidity only up to the saturation point, the Kytola Oilan A4 streches way beyond this. As commonly known, once the saturation point is reached, humidity transforms to highly damageable free water. In worst cases salty sea water may enter the process and cause corrosion and premature oil aging. Oilan A4 is able to measure free water and react even to minor changes in the oil. Hundreds of sold Kytola Oilan A4's operating in the marine and offshore industry speak for themselves.

React before failure

The OILAN A4 Water in Oil Analyzer is an IR-absorbance-based online instrument for measuring the absolute water content in oil (ppm).

As the measurement is performed online, the response is continuous and fast, which is crucial in order to detect sudden changes in the water content and to be able to react before any failures of the lubricated equipment occur. Time-consuming and expensive sampling and laboratory analyses are also avoided.

169 Kytola Oilan A4
Insatech Medarbejdere Website MSR
For technical questions

Martin Søvind Jensen


Tel: +45 2761 4502

Email: Martin.Sovind@insatech.com

Write to Martin

Insatech Medarbejdere Website ASMI
For commercial inquiries

Astrid Mihut


Tel.: +45 5537 2095

Email: Marine@insatech.com

 

Contact us now

Specifications
Measuring range

0...5000 ppm

Accuracy

±30 ppm within calibrated measuring range and calibration conditions

Ambient temperature

5...60 °C

Oil Sample temperature

5...60 °C

Oil connections

G or NPS 1/4"

Oil purity classification

19/17/14, ISO 4406

Oil viscosity

10...680 cSt

Oil sample pressure

1...10 bar

Enclosure

Aluminium

Supply voltage

24 VDC

Output

4...20 mA

Alarm relay

NO or NC (selectable using KVM software), max. 48 VDC / 100 mA

Communication

Modbus RTU (RS485)

IP Class

IP 65

Weight

4.05 kg including hoses

Product specifications and manuals

Didn't you find what you were looking for? 

If you are looking for some specific material, please write to us. Then we will try to find it for you, and send it as soon as possible.

Fill out the contact form 

Consent for storing of submitted data *


This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

To top

Search