Insatech logo
Power supply

2 x 24V DC -25/+30%, ripple ≤ 5%, automatic fuse

Power consumption

approx. 25W

Operating temperature

-20 ... +85 °C

Storage temperature

-20 ... +85 °C

Relative humidity

<90 %, non-condensing

Protection acc. DIN 60529

Monitoring box IP 65, Optical sensors IP 67

Terminals

Conductor cross section 0.14 ... 1.5mm2

Housing material

Tube element steel, monitoring box and optic sensors aluminum

Weight

Monitoring box approx. 1.3 kg, engine specific tube element approx. 5 ... 22 kg

EMS-standard

Generics no. 55016 and 55022, Safety rules acc. EN 61000-4, -6, Rules for type approval: DNVGL

 

Certificates
  • DNVGL
  • ABS
  • LR
  • RINE
  • BC

 

External Input: Engine-Signal (On/ Off)

By using a voltage signal or as input contact. Alternative: signal can be set by CAN

Crankcase pressure

Burden max. 500R

Oil mist

Burden max. 500R

Linearity

max. ± 0,25% of final value

Reaction time

Approx. 300 ms

1x Alarm/ Trip- Relay

Mechanical, NO/ NC, free programmable

Max. switching power

60W, 125 VA

Max. switching voltage

220 VDC, 250 VAC

Max. switching current

2A DC/AC

Exp. Life/ min. operations

1,000,000

Contact material

gold-plated silver

1x System-Error relay

Self-monitored PhotoMOS-relay, short-circuit protected

3x Status-Message relays

PhotoMOS-relay, short-circuit protected, free confingurable (Pre-alarm, Pressure alarm, Reserve)

Max. switching current

500 mA

Max. switching voltage

7 ... 60V AC/DC

Ethernet

For display and parameter settings galvanic isolated

Link speed

max. 100 Mbit/s

CAN

Galvanic isolated

Protocol

CANopen, J1939

Adressing (Node ID)

Adjustable 1 ... 127

Transmission rate

Adjustable 20 kBaud ... 1 MBaud