Insatech logo
Technical Specifications
Type

Absolute and Gauge Pressure Transmitter

Measuring range

From 100 mbar to 500 bar distributed over 4 measuring cells

Output

Output signal two-conductor 4 - 20 mA DC with digital communication

Ambient temperature

Effects per 28 °C Change

  • ±(0.15% of Span + 0.15% of URL) for A, B and C capsule
  • ±(0.15% of Span + 0.15% of 50 MPa) for D capsule
Accuracy

± 0.055% of span

Monitoring

Via BRAIN or HART communications and selfdiagnostics. FOUNDATION Fieldbus, PROFIBUS PA and 1 to 5 V DC with HART (Low Power) protocol types are also available.

Stability (All normal operating condition)
  • EJA530E: ±0.1% of URL for 10 years
  • EJA510E: ±0.2% of URL for 10 years
Power Supply Effects

±0.005 % per Volt (from 21.6 to 32 V DC, 350Ω)

Communication
  • BRAIN or HART protocol overlaid in 4 - 20 mA signal
  • Opportunity for the Fieldbus Foundation and Profibus PA
Certifications
  • Marine: LR, ABS, BV and DNV-GL
  • ATEX, FM, CA, IECEx
  • TUV SIL2 / SIL3
To top