Insatech logo

Here we can provide you with all calibration solutions such as (Temperature, Pressure, Weight …..etc) . Aslo we have the Torque measurement system to prevent your ship from breakdown cost. The flowmeters and vibrations sensors are very important to provide you with accurate measuring .

Read about Marine instruments

248RESULTATER NULSTIL
Insatech Siemens SITRANS LCS050 Capacitive Point Level Switch 7ML5772 16 9

Capacitive level switch - Liquids

Siemens SITRANS LCS050 Capacitiv Level Switch

SITRANS LCS050 is an affordable ultra-compact capacitive level switch designed for point level detection in confined spaces, water-based liquids, slurries, and foam.

Insatech Siemens SITRANS LCS100 Capacitive Point Level Switch 7ML700 7ML701 7ML702 7ML703 16 9

Capacitive level switch - Liquids

Siemens SITRANS LCS100 Capacitive Level Switch

A versatile level switch that detects level and interface in liquids, solids, and slurries, even in the presence of foam. Its compact design makes it ideal for locations with limited space, and it is available in both rod and cable versions.

Insatech Siemens Pointek CLS200 Point Level Or Interface 7ML5630 7ML5631 7ML5632 7ML5633 7ML5634 16 9

Capacitive level switch - Liquids and solids

Siemens Pointek CLS200 Level Switch

The Pointek CLS200 is a capacitive level switch that can detect liquids, solids, slurries, foam, and interfaces, and is available in both rod and cable versions. It can be used in tanks and pipes in the oil and gas, cement, chemical, food, marine and general industries. It measures up to 30 m.

Insatech Siemens Pointek CLS300 Point Level Switch 7ML5650 7ML5651 7ML5652 16 9

Capacitive level switch - Liquids and solids

Siemens Pointek CLS300 Capacitive Level Switch

The Pointek CLS300 is a capacitive level meter and switch with the option for rod or cable extension up to 25 m. The CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding applications with high pressure (35 bar) and temperature (+400 °C).

Insatech Siemens SITRANS LC300 Capacitance Level 7ML5670 7ML5671 7ML5673 16 9

Capacitive level - Liquids and solids

Siemens SITRANS LC300 Capacitive Transmitter

The SITRANS LC300 is a capacitive continuous level meter for liquid, interface, and solid applications. It is ideal for standard applications in industries such as chemical, petrochemical, food, beverage, water, wastewater, raw materials, and cement. It can measure up to 25 m, 200 °C, and 35 bar.

Insatech Siemens SITRANS LPS200 Rotary Paddle Switch 7ML5725 7ML5726 7ML5727 7ML5728 7ML5730 16 9

Level Switch Solids

Siemens SITRANS LPS200 Rotary Level Switch

A rotary level switch for level and material detection in bulk solids such as grain, feed, cement, plastic granules, and wood chips. It handles densities as low as 15.06 g/l with the optional rectangular paddle. It can be extended up to 10 m and withstands temperatures up to 600 °C and 10 bar.

Insatech Siemens SITRANS RD100 Digital Display 7ML5741 16 9

Signal processing

Siemens SITRANS RD100 Digital Display

RD100 is a 2-wire loop-powered, NEMA 4X enclosed remote digital display for process instrumentation.

Insatech Siemens SITRANS RD150 Digital Display 7ML5742 16 9

Signal processing

Siemens SITRANS RD150 Digitalt Display

SITRANS DR150 is a digital 4...20 mA HART display for remote reading of process instrumentation. The housing is available in plastic, aluminum, and stainless steel with up to IP68 protection. The display can be used to show level, flow, pressure, temperature, and weight.

Insatech Siemens SITRANS RD200 Digital Display 7ML5740 16 9

Signal processing

Siemens SITRANS RD200 Digital Display

RD200 is a universal display for level, flow, pressure, temperature, weighing, and other process instruments. The display accepts a single input of current, voltage, thermocouple, and RTD.

No results found

Marine Instruments

The importance of using proper instrumentation Electrical and mechanical instrumentation invovles design, control and implementation of devices that can measure physical quantities. There is a huge amount of thought behind the proper instrument and installation choices for each small or larger measuring point. All vessels generally use state of the art instrumentation and equipment to manage everything from the engines, steering and navigation system. When the equipment malfunctions it can have a huge impact on the operational efficiency and can cause massive downtime that can put the vessel behind schedule. A broken viscoity sensor can cause wrong engine combustion, wrong additive dosing can reduce fuel efficency or worse; lubrication properties of various lubration oils. A ballast that isnt filled appropriately after loading can impact vessel stability and leaks and dangerous pressure levels in fuel tanks can impact enginre operation or even lead to disaster.

Proper Use of the Correct Instrumentation Is Important

– a Sensor Is Not Just a Sensor

Today’s fleet is generally becoming highly sophisticated operations with equally sophisticated equipment on board. And controlling all this sophisticated equipment correctly and preventing breakdowns is crucial to a smooth and cost-effective operation. Choosing the correct instrument for measuring the processes on board is not only a good idea seen from a practical aspect, but investing the time and possibly a little extra money on instrumentation that is ideal for the task, can ultimately save the vessel both cost and unnecessary interference for the crew on board.

Measurements are used all over the modern ship in order to keep equipment running at optimum conditions. Everything from critical installations such as main engines, auxiliary engines, steering and navigation to other installations such as cranes, cargo pumps and wastewater handling can and should be monitored with optimization in mind. Optimization of processes on board a ship can contribute to better earnings and lower emissions – even if the realized optimization is only constituted by fewer unplanned interruptions such as maintenance works and breakdowns.

A malfunctioning viscosity sensor can cause lower exploitation of the fuel due to wrongful combustion; a hydraulic failure on a crane can cause delay in port operations and interrupt the planned schedule; incorrect ballast control can impact vessel stability and trim causing anything from slightly lower performance to accidents and undetected leaks in cargo and fuel tanks can cause dangerous situations or even lead to disaster.

Choosing the correct instrument for a specific task can be challenging, as a myriad of variations of a single instrument often exist. And just going by the most expensive option or for something that has been recommended, is not always the right way, as the process and media in which the instrument should be installed is what determines what measurement principle and setup should be chosen. Degradation is caused very differently based on what the instrument is exposed to, and one instrument suited for one place on board might be unsuitable for another; a different pressure might cause inaccurate reading or mechanical failure and a different media could do the same. 

Across the specialists at Insatech, we have the knowledge and experience to find the right instrument for your specific application as well as we can guide you to install it correctly. Making your operation as smooth and efficient as possible is always our goal with our counselling and services, as your success leads to our success!

Back to product overview

To top

Search