| Model/ Type | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Pressure | 450: in bar 451: in H2O |
||||||||||||||||||
| Input | [mH2O] [bar] 4000: 0.4 |
||||||||||||||||||
| Housing | 1: stainless steel 1.4404 (316L) 9: customer |
||||||||||||||||||
| Diaphragm | 1: stainless steel 1.4435 (316L) 9: customer |
||||||||||||||||||
| Output | 1: 4 … 20 mA / 2-wire E: intrinsic safety 4 … 20 mA / 2 wire 3: 0 … 10 V / 3-wire 9: customer |
||||||||||||||||||
| Seals | 1: FKM 3: EPDM DVGW/KTW 3T: EPDM (Note 1) 9: customer |
||||||||||||||||||
| Accuracy | standard for pN ≥ 0.1 bar 1: 0.1 % FSO standard for pN < 0.1 bar B: 0.2% FSO 9: customer |
||||||||||||||||||
| Electrical connection | 1: PVC-cable (grey, Ø 7.4 mm) (Note 2) 2: PUR-cable (black, Ø 7.4 mm) (Note 2) 3: FEP-cable (black, Ø 7.4 mm) (Note 2) 4: TPE-U-cable (blue, Ø 7.4 mm) (Note 2) DVGW/KTW F: TPE-U-cable (blue, Ø 7.4 mm) (Note 1, 2) 9: customer |
||||||||||||||||||
| Cable length | 999: in m |
||||||||||||||||||
| Special version | 111: standard 999: customer |
||||||||||||||||||
| Notes | 1: drinking water certification only possible with EPDM seal (code 3T) in combination with TPE-U cable (code F); not possible with IS version (explosion protection) 2: shielded cable with integrated ventilation tube for atmospheric pressure reference |
||||||||||||||||||