The Sensitron SMART 3 NC is a fixed gas detector from the SMART 3 series, designed for non-classified areas including engine rooms and refrigeration plants. It detects flammable gases, toxic gases, and CO₂ using catalytic, electrochemical, and infrared sensors, and outputs a standard 4–20 mA signal with optional relay outputs and RS485 / Modbus communication. The SMART 3 NC requires a control panel and is not a standalone system.

Key Advantages:

  • Designed for non-classified areas — no ATEX requirement
  • Detects flammable gases, toxic gases, and CO₂
  • Catalytic, infrared, and electrochemical sensor options
  • Standard 4–20 mA output
  • Optional 1- or 3-relay outputs and RS485 / Modbus communication
  • Continuous self-diagnostics
  • Requires a compatible Sensitron control panel

Request a quote for the Sensitron SMART 3 NC

Detectable gases

The SMART 3 NC is available in sensor-specific variants. The gas type must be matched to the correct sensor at time of order.

Catalytic sensor: Flammable gases: methane (CH₄), LPG, and other hydrocarbons

Electrochemical cell: Toxic gases: carbon monoxide (CO), nitrogen dioxide (NO₂)

Infrared (IR): CO₂

Fixed Gas Detection for Engine Rooms and Refrigeration Plants

Engine rooms and refrigeration machinery spaces present distinct gas hazards depending on the fuel type, refrigerant used, and ventilation conditions on site. Carbon monoxide from combustion, methane or LPG from fuel systems, CO₂ from industrial processes, and nitrogen dioxide from engine exhaust are all gases that may accumulate in non-classified enclosed spaces and require fixed detection.

The SMART 3 NC covers all of these gas types within a single detector platform, making it a practical specification for facilities where multiple gas hazards need to be monitored across different points in the same installation. Its standard 4–20 mA output integrates with most control panel architectures, and optional RS485 / Modbus communication supports integration with building management and site monitoring systems.

As a panel-dependent detector, the SMART 3 NC is typically specified as part of a broader Sensitron system alongside a compatible control panel. Contact our team for advice on control panel selection and system configuration.

SMART 3 NC vs SMART 3 R - Choosing the Right SMART 3 Detector

Both the SMART 3 NC and SMART 3 R are from the SMART 3 series for non-classified areas and share the same core sensor platform. The distinction is in gas type focus and feature set:

SMART 3 NC - covers flammable gases, toxic gases, and CO₂. Relay outputs and RS485 are optional. Requires a control panel. The appropriate choice where the primary hazards are combustion gases, LPG, or CO₂ in a panel-managed installation.

SMART 3 R - focused on refrigerant gas detection with broader sensor coverage including A2L refrigerants. Includes RS485 and 3 relay outputs as standard, and an integrated data logger. F-Gas Regulation compliant. The appropriate choice for refrigerant leak detection applications and installations requiring data logging or standalone relay output capability.

Not sure which model fits your installation? Contact our team and we will advise based on your gas hazards, system architecture, and any regulatory requirements that apply.

Contact us for product selection advice

Have a question about the Sensitron SMART 3 NC?

Our technical team can advise on sensor configuration, control panel compatibility, and whether the SMART 3 NC or another model in the SMART 3 series is the right specification for your installation.

Insatech Medarbejdere Website MSR
For technical questions

Martin Søvind Jensen


Tel: +45 2761 4502

Email: Marine@insatech.com

Write to Martin

Test Af Websitebillede FREJ ANAN HNI
For commercial inquiries

Our team of Sales Specialists


Tel.: +45 5537 2095

Email: quotes@insatech.com

 

Contact us now

We Deliver Directly to End Customers, Resellers, and Agents – Globally

At Insatech, we are proud to offer our high-quality products to all customers worldwide. Whether you’re an end customer, a reseller, or an agent, you can purchase directly from us.

By choosing us, you gain direct access to all our products, eliminating the need for intermediaries. Our global distribution possibilities ensure fast and reliable delivery to your doorstep, wherever you are.

We strive to make it easy for you as an end consumer to find the products you are looking for while supporting agents and resellers looking to grow their business. Whether you’re buying for your use or resale, we’re here to meet your needs.

Discover how simple it is to work directly with a trusted global distributor – shop with confidence at Insatech today!

Contact us here

Technical Specifications
Series

SMART 3 - non-classified areas

Application

Non-classified areas, engine rooms, refrigeration plants

Gas types detected

Flammable gases, toxic gases, CO₂

Sensor technologies

Catalytic bead, infrared (IR), electrochemical cell

Output signal

Standard 4–20 mA (3-wire)

Relay outputs

Optional 1- or 3-relay output card

Communication

Optional RS485 / Modbus protocol

Control panel

Required - not a standalone system

BIM files

Available

Self-diagnostics

Continuous

Datasheets

  • SMART 3 NC - Catalytic Sensor
    English | pdf
  • SMART 3 NC - Electrochemical Cell
    English | pdf
  • SMART 3 NC - Infrared Sensor
    English | pdf

Didn't you find what you were looking for? 

If you are looking for some specific material, please write to us. Then we will try to find it for you, and send it as soon as possible.

Fill out the contact form 

Consent for storing of submitted data *


This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

To top

Search