Insatech logo
Remineralizer Systems Parker Watermakers 1X1

Remineralizer Systems

The Remineralizer Systems from Parker Watermakers offer pH neutralization of RO water and are specifically engineered to operate with Village Marine PW and SW Series Watermakers, used in Offshore Applications.

Standard Features:

  • pH Neutralization
  • Self-limiting calcite dosing
  • Reduces Water Aggressiveness
  • Low Maintenance

We deliver directly and globally to end-users, agents, and resellers.
Contact us at quotes@insatech.com.

Get a quote

Protect Pipes with Balanced, Mineralized Water

The Parker Village Marine Tec. Remineralizer ensures safe, balanced water quality by gradually dissolving calcite into product water. This process raises the pH to near-neutral levels and adds mineral hardness, protecting metal pipes and fixtures from corrosion caused by low pH water.

Built for durability, the unit features a spun-wound fiberglass composite tank with a polyethylene liner, PVC schedule 80 piping connections, and a carbon steel base.

Important Maintenance Note:
Calcite media is consumed over time and must be replenished periodically. The unit comes with an initial fill of calcite media.

Remineralizer – Balance pH and Hardness, Effortlessly

The Remineralizer improves water quality by adding a controlled amount of hardness and adjusting the pH toward neutral. It is typically installed downstream of a reverse osmosis (RO) system, before the fresh water storage tanks, ensuring optimal water balance without the need for additional pumping.

Function and Operation

The Remineralizer slowly dissolves calcite media into the product water, raising hardness and stabilizing the pH near neutral. This process is self-limiting, meaning:

  • Only a small amount of hardness is added to avoid over-treatment.
  • The system operates without requiring active controls or adjustments.

Inquiry the product and contact us now

Remineralizer Systems Parker Watermakers Drawing
Remineralizer Systems Parker Watermakers Platform

Stop Corrosion Before It Starts

Neutralizing reduces water “aggressiveness,” helping to protect metal pipes, fixtures, and system components from corrosion and wear.

By restoring buffer capacity, the Remineralizer ensures your fresh water is safer for your system and longer-lasting.

Need more information? Contact us now

Different Models - Same Excellence

We have made it easy for you to see the different models available of the Remineralizer Systems from Parker Watermakers. They are listed below with the specifications.

RMF-8
Part Number

90-8215

Inlet/Outlet

1" ANSI Flange

Max Flow GOM/LPM

6/23

Dimensions Inch/cm (LxWxH)

24/61 x 24/61 x 73/185

Dry Weight lbs/kg

500/250

RMF-20
Part Number

90-8544

Inlet/Outlet

1" ANSI Flange

Max Flow GOM/LPM

14/53

Dimensions Inch/cm (LxWxH)

24/61 x 24/61 x 73/185

Dry Weight lbs/kg

780/355

RMF-40
Part Number

90-8811

Inlet/Outlet

1.5" ANSI Flange

Max Flow GOM/LPM

25/94

Dimensions Inch/cm (LxWxH)

26/66 x 24/61 x 83/160

Dry Weight lbs/kg

880/400

Your Benefits of the Watermakers Systems

Below we have gathered a few of the benefits of a Parker Water Purification Watermaker.

Less weight, lower fuel costs, higher speeds:

Sailing with a full water tank, or an additional 1,700 pounds, leads to squandered fuel, reduced speeds, and abbreviated voyages. With this watermaker, you can cruise swifter and longer while generating fresh water right onboard. Our systems not only save boaters time and money but also optimize yacht performance.

Cruise without limits or boundaries:

Having this watermaker onboard means you can bypass scheduling your boating ventures around marina stops. Cruise directly to your destination or venture to boundless distances without the necessity of replenishing fresh water supplies.

Fresh water wash downs:

Using Water Purification water for wash downs proves exceptionally efficient in safeguarding your yacht's exterior, potentially enhancing its overall value. Parker Water Purification water functions like a sponge, adeptly absorbing and rinsing away all undesirable sea salt and minerals, leaving surfaces spotlessly clean and free of water spots.

Convenient for every boating activity:

Regardless of whether you utilize it for drinking, showering, or cleaning your yacht, having a Water Purification watermaker offers endless opportunities to save money and enjoy more leisure time. With such advantages, how can any boater justify not owning this Water Purification watermaker?

Get more inforamtion - contact us now!

Remineralizer Systems Parker Watermakers 16X9
Remineralizer Systems Parker Watermakers Drawing
Remineralizer Systems Parker Watermakers 16X9
Remineralizer Systems Parker Watermakers Drawing

Installing your Reverse Osmosis System

The Reverse Osmosis(RO) system needs installation in a dry, sheltered area shielded from direct weather exposure. Adequate drainage should be ensured beneath the RO unit to facilitate water runoff during maintenance or repairs.

Rosystem Location 1 Parkerwatermakers 1024 16X9 Rosystem Location 2 Parkerwatermakers 1024 16X9

From Theory to Practice: Decoding Reverse Osmosis Mechanisms

The theory in short:

  • Osmosis: natural process involving semi-permeable membrane
  • Desalination: balances solution concentrations through membrane
  • Reverse Osmosis: high pressure reverses flow for purer solution
  • Feedwater concentration increases in Reverse Osmosis
  • Operating pressure: at least double membrane's osmotic pressure
  • Seawater composition: sodium chloride, calcium, sulfate
  • Total Dissolved Solids (TDS): averages 32,000 to 35,000 ppm.

Let’s take a deep dive into the theory.

Understanding Osmosis: Nature's Filtering Process

Osmosis, a natural phenomenon, occurs when a semi-permeable membrane separates a pure solution from a concentrated one (where a semi-permeable membrane selectively allows passage of substances). Each liquid carries an inherent potential closely tied to the nature and quantity of solids dissolved within it. This potential, termed osmotic pressure, rises with the relative concentration of a solution. Consequently, a concentrated solution exhibits a higher osmotic pressure compared to a pure solution.

Reverse Osmosis: Engineering Pure Water Solutions

In a desalination setup, the less concentrated solution balances the concentrations of both solutions by moving across the membrane. Once adequate pure solution migrates across the membrane to equalize the inherent potential difference, the flow of purer solution ceases.

However, if pressure on the concentrated solution exceeds the osmotic pressure, fluid flow reverses. This phenomenon, known as Reverse Osmosis, is achieved by artificially pressurizing the more concentrated solution using a high-pressure pump. In such a system, the concentrated solution (commonly called feedwater) becomes even more concentrated as pure water moves across the membrane to the permeate side.

Disregarding the impact of feedwater temperature and salinity, the operating pressure typically required to produce significant quantities of pure water is at least double the osmotic pressure of the membrane utilized.

Seawater Composition: Total Dissolved Solids Overview

Seawater encompasses various solids dissolved within it. The predominant component is typically ordinary table salt, sodium chloride. Additionally, other minerals found in solution often comprise diverse compounds of calcium and sulfate. The collective sum of these dissolved solids in a given water sample is termed Total Dissolved Solids or TDS. Seawater typically registers between 32,000 to 35,000 ppm (parts per million) TDS on average, although deviations of around 5000 ppm are commonplace across different regions globally. The primary objective of any desalination process is a notable reduction in the concentration of dissolved solids in water.

It's important to acknowledge that no system can entirely eliminate all dissolved solids from seawater. Instead, the system is engineered to reject approximately 99% of the TDS, allowing only 1% of the 35,000 ppm TDS in seawater to permeate into the product water. This results in water containing less than 500 ppm, the recommended TDS level for drinking water. A system configured in this manner is described as having a salt passage percentage of 1% or a salt rejection rate of 99%.

Membrane Magic: Inside the High-Tech World of Reverse Osmosis

The purified and strained raw water, now termed feedwater, enters the inlet of the high-pressure pump. This pump elevates the feedwater pressure to 56-65 BAR (800 - 950 psi), the standard pressure necessary for optimal system recovery. Subsequently, the pressurized feedwater is directed into the membrane pressure vessels, forming an array. This array comprises fiberglass pressure vessels, each housing RO membrane elements.

Within the membrane elements, reverse osmosis occurs as the pressurized feedwater flows. The feedwater is bifurcated into two streams: the high purity product stream (referred to as the product) and the increasingly concentrated reject stream (referred to as the reject).

Want to know more? Contact us now!

Maintaining RO Efficiency: Environmental Factors at Play

The table below demonstrates how alterations in temperature, salinity, and pressure impact both the quality and quantity of permeate generated by the RO system.

Should the salt concentration in the feedwater decrease, it's advisable to limit the increase in product water flow rate to no more than 20% above the rated flow. To maintain the rated flow in applications with brackish water or freshwater, adjustments to the Membrane Reject pressure may be necessary.

In scenarios where the feedwater salinity drops below the nominal level (e.g., near river mouths or in estuaries), the RO system can be fine-tuned to uphold a consistent permeate output. This adjustment can be achieved by manually controlling system pressure using the back-pressure regulator valve positioned in the system brine piping. To ensure prolonged pump life and minimal membrane fouling, Parker suggests not exceeding 9 psi, except in cases of extremely low temperature feed water.

BE AWARE that operating the unit at over 120% of its rated capacity in low salinity water can cause membrane damage.

Need more information? Contact us here.

General Watermakers FAQ

Accessory FAQ

Installation FAQ

Maintenance FAQ

Insatech Medarbejdere Website MSR
For technical questions

Martin Søvind Jensen


Tel: +45 2761 4502

Email: Martin.Sovind@insatech.com

Write to Martin

Insatech Medarbejdere Website ASMI
For commercial inquiries

Astrid Mihut


Tel.: +45 5537 2095

Email: Marine@insatech.com

 

Contact us now

We Deliver Directly to End Customers, Resellers, and Agents – Globally

At Insatech, we are proud to offer our high-quality products to all customers worldwide. Whether you’re an end customer, a reseller, or an agent, you can purchase directly from us.

By choosing us, you gain direct access to all our products, eliminating the need for intermediaries. Our global distribution possibilities ensure fast and reliable delivery to your doorstep, wherever you are.

We strive to make it easy for you as an end consumer to find the products you are looking for while supporting agents and resellers looking to grow their business. Whether you’re buying for your use or resale, we’re here to meet your needs.

Discover how simple it is to work directly with a trusted global distributor – shop with confidence at Insatech today!

Contact us here

Specifications & Manuals

  • Data Sheet - Remineralizer Systems - Parker Watermakers
    English | pdf
  • Brochure - Water Purification Product Catalog - Parker Watermakers
    English | pdf
  • Article - Watermakers FAQ - Parker Watermakers
    English | pdf

Didn't you find what you were looking for? 

If you are looking for some specific material, please write to us. Then we will try to find it for you, and send it as soon as possible.

Fill out the contact form 

Consent for storing of submitted data *


This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

General Technical Specifications

Brand

Village Marine

Application

Commercial

Product Type

Post-filtration Treatment

Connection Type

1-1.5" ANSI Flange

Flow Rate

23 to 94 L/min

Weight

500-880 lbs/250-400 kg

To top

Search