Insatech logo
Sensitron SMART 3G C2 Insatech (3)

The Sensitron SMART 3G C2 is a fixed gas detector for Zone 1 hazardous areas, certified to ATEX Category 2 and rated SIL2 (hardware) / SIL3 (software). It detects flammable, toxic, VOC, and refrigerant gases across four sensor technologies - catalytic, infrared, electrochemical, and PID - and includes an integrated data logger exportable via STS/CKD-OLED or STS/CSW+ software. 

Key Advantages:

  • Zone 1 / ATEX Category 2 certified for hazardous area installations
  • Four sensor technologies covering flammable, toxic, VOC, and refrigerant gases
  • Integrated data logger - exportable via STS/CKD-OLED or STS/CSW+
  • BIM files available for BIM-documented installations
  • SIL2 / SIL3 rated for functional safety requirements
  • Standard 4–20 mA output with optional 1- or 3-relay output card
  • Optional RS485 / Modbus communication
  • Continuous self-diagnostics with zero follower drift compensation

We deliver directly and globally to end-users, agents, and resellers.
Contact us at quotes@insatech.com.

Request a quote for the Sensitron SMART 3G C2

Detectable gases

The SMART 3G C2 is available in sensor-specific variants. The gas type must be matched to the correct sensor at time of order.

Catalytic sensor: Flammable gases: methane (CH₄), LPG, butane, propane, and other hydrocarbons

Electrochemical cell: Toxic gases and oxygen: carbon monoxide (CO), ammonia (NH₃), oxygen (O₂), and others

Electrochemical cell (intrinsically safe): Chlorine (Cl₂), sulphur dioxide (SO₂), nitrogen dioxide (NO₂)

Infrared (IR): Flammable gases, CO₂, SF₆, and refrigerant gases

PID: VOC (volatile organic compounds)

Zone 1 Gas Detection Across Marine and Industrial Installations

The SMART 3G C2 shares the same Zone 1 / Category 2 certification and sensor platform as the SMART 3G D2 and C2 LD, making all three suitable for the same classified hazardous areas. The choice between models comes down to housing form factor, data logging requirements, and specific installation constraints - rather than gas type coverage or certification level, which are consistent across the range.

For marine applications, Zone 1 hazardous area detectors are typically required in engine rooms, pump rooms, battery compartments, refrigeration machinery spaces, and other enclosed areas where flammable or toxic gas accumulation is possible in normal operating conditions. The C2's wide sensor range - covering ammonia, methane, carbon monoxide, oxygen, refrigerants, and VOCs - makes it a practical choice for installations covering multiple gas hazard types within a single vessel.

Sensitron SMART 3G C2 Insatech

Choosing Between the SMART 3G C2, C2 LD, and D2

All three models are Zone 1 / ATEX Category 2 detectors with identical sensor technology options and certifications. The practical differences are:

SMART 3G D2 - Standard Zone 1 detector without data logger. The D2 features a 4-digit display and 5 status LEDs as standard, and non-intrusive calibration via magnetic pen.

SMART 3G C2 - Zone 1 detector with integrated data logger, exportable via STS/CKD-OLED or STS/CSW+. Also available with BIM files for building information modelling documentation.

SMART 3G C2 LD - Zone 1 detector with integrated data logger in a different housing configuration from the C2. Suited to installations where the C2 LD enclosure is the preferred or required form factor.

If you are unsure which model suits your installation or vessel type, contact our team and we will advise based on your specific requirements and any existing Sensitron equipment on board.

Contact us for product selection advice

Have a question about the Sensitron SMART 3G C2?

Our technical team can help you confirm the right model for your installation, select the correct sensor configuration, and provide pricing and availability.

Insatech Medarbejdere Website MSR
For technical questions

Martin Søvind Jensen


Tel: +45 2761 4502

Email: Marine@insatech.com

Write to Martin

Test Af Websitebillede FREJ ANAN HNI
For commercial inquiries

Our team of Sales Specialists


Tel.: +45 5537 2095

Email: quotes@insatech.com

 

Contact us now

We Deliver Directly to End Customers, Resellers, and Agents – Globally

At Insatech, we are proud to offer our high-quality products to all customers worldwide. Whether you’re an end customer, a reseller, or an agent, you can purchase directly from us.

By choosing us, you gain direct access to all our products, eliminating the need for intermediaries. Our global distribution possibilities ensure fast and reliable delivery to your doorstep, wherever you are.

We strive to make it easy for you as an end consumer to find the products you are looking for while supporting agents and resellers looking to grow their business. Whether you’re buying for your use or resale, we’re here to meet your needs.

Discover how simple it is to work directly with a trusted global distributor – shop with confidence at Insatech today!

Contact us here

Technical Specifications
Application

Zone 1, Category 2 (classified and non-classified areas)

Gas types detected

Flammable, toxic, VOC, refrigerant

Sensor technologies

Catalytic bead, infrared (IR), electrochemical cell, PID

Output signal

Standard 4–20 mA (3-wire)

Relay outputs

Optional 1- or 3-relay output card

Communication

Optional RS485 / Modbus protocol

Data logger

Yes - exportable via STS/CKD-OLED or STS/CSW+

BIM files

Available

Calibration

Standard calibration procedure

Self-diagnostics

Continuous

Drift compensation

Zero follower function

ATEX certification

II 2G Ex db IIC T5 Gb (standard)

ATEX (IS version)

II 2G Ex db [ib] IIC T6 Gb (intrinsically safe sensors)

Optional ATEX

II 2G D (dust) with optional adapter

SIL rating

SIL2 hardware / SIL3 software

Datasheets

  • SMART3G-C2 - Catalytic Sensor
    English | pdf
  • SMART3G-C2 - Electrochemical Sensor
    English | pdf
  • SMART3G-C2 - Intrinsically Safe Detector
    English | pdf
  • SMART3G-C2 -Infrared Sensor
    English | pdf

Didn't you find what you were looking for? 

If you are looking for some specific material, please write to us. Then we will try to find it for you, and send it as soon as possible.

Fill out the contact form 

Consent for storing of submitted data *


This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

To top

Search